  diesel generator set mtu 10v1600 ds560 400 C 230 v/562 kva/50 hz/standby power series 1600 C mtu 10v1600 product highlights optional equipment and ? nishing shown. standard may vary. // bene? ts - industry-leading average load factor - low fuel consumption - emissions optimizations available - high availability and reliability - outstanding load acceptance - long maintenance intervals // support - global product support offered // standards - engine-generator set is designed and manufactured in facilities certi? ed to standards iso 2008:9001 - generator set complies to iso 8528 and full? lls performance level g3 - generator meets bs5000; nema mg 1; iso; din en and iec standards - nfpa 110 // available optimizations - exhaust emission eu 97/68 ec stage iii a - nea singapore for off road diesel engines (orde) - arai cpcb stage ii - fuel optimized // wide standard scope of supply - 4p circuit breaker - island operation control panel - integrated fuel tank - industrial silencer (15 db(a)) - batteries & battery charger // complete range of accessories available - sound attenuated enclosure - fuel system accessories - control panel & ats - range of additional electronical options // warranty - standard 36 months warranty after shipment
2 // / / mtu 10v1600 ds560 / 50 hz / 400 - 230v application data ? // engine manufacturer mtu model 10v1600g80f type 4-cycle arrangement 10-v displacement: l 17.5 bore: mm 122 stroke: mm 150 compression ratio 17.5 rated rpm 1500 engine governor ecu 8 gross power: kwm 493 air cleaner dry // fuel system max. fuel ? ow: l/h 342 fuel tank capacity: opu (epu) in l 740 (740) autonomy: h 9 // fuel consumption l/h at 100% of power rating: 117.52 // liquid capacity total oil system: l 60.5 total coolant capacity: l 94 // generator generator brand mecc-alte generator type hm355b1 insulation class h-class bearing single bearing enclosure ip23 m voltage regulation a.v.r. (electronic) exciting system self-excited, brushless // electrical electric system volts dc 24 number of batteries 2 capacity: ah 2x 75 // air requirements aspirating: m 3 /min 28.8 cooling air ? ow: m 3 /s 10.9 // exhaust system gas temp. (stack): c 540 gas volume at stack temp.: m 3 /min 82.8 maximum allowable back pressure: kpa 15 // cooling/radiator system ambient capacity of radiator in opu (epu): c 50 (50) pressure on rad. exhaust: kpa 0.2 heat rejection to coolant: kw 227 ? technical data is for a fuel-optimized unit.
3 // / / mtu 10v1600 ds560 / 50 hz / 400 - 230v // engine 4- strokes diesel engine flywheel housing sae 1 flywheel 14'' four-valve, overhead camshaft piston cooling via oil spray nozzle forged crankshaft & connecting rods oil pan lube oil circulation pump dry exhaust manifolds hot components and radiator guards mobile components guards lube oil filter represents standard features ? represents optional features standard and optional features // system ratings (kw/kva) mtu 10v1600 ds560 standby operation voltage 400 v phase three phase hz 50 kwel* 448.8 kva** 561 rated amps 809.7 * cos phi = 1,0 ** cos phi = 0,8 also available for following voltages 380v & 415v - for details please contact your local mtu onsite energy de aler. // fuel system fuel main filter fuel pre-filter with water seperator common rail fuel injection integrated fuel tank (level sensor and drain cap incl.) ? automatic fuel transfer pump ? heavy-duty fuel pre-filter with water seperator ? 3-way valve for fuel filling ? fuel cooler // generator 3-phase, syncronos, brushless, self exciting, self regulating, self ventilating alternator ? winding temperature sensors ip23 m protection degree ? ip23 protection cover ? bearing temperature sensors insulation class h ? anti condensation heater ? permanent magnet // control panel & electric options control and power electric panel, with measurements devices and contoller ? ats (automatic transfer switch) ? control version for parallel operation ? control version for synchronizing a single genset with mains ? programmable timer for mm7 and mc7 ? remote display ? expansion module for can communication ? change over power supply for mc7 ? input output/led expansion modules for deepsea controllers ? modbus connection to customer systems tcp/ip ? control version for synchronizing with mains without blackout ? converter kits can to rs485/usb/lan
4 // / / mtu 10v1600 ds560 / 50 hz / 400 - 230v represents standard features ? represents optional features standard and optional features, continuation // circuit breaker/power distribution 4 poles manual circuit breaker (motorized with deepsea controllers) // starting/charging system 24v electric system starting batteries installed pre-heating resistance/jacket water heater battery charging alternator battery disconnector battery charger // air intake system exhaust turbochargers set of dry-type air filters with contaiment indicator intercooler, integrated in radiator ? heavy duty air filter with automatic dust evacuation // exhaust system industrial silencer 15 db(a) ? residential silencer 35 db(a) ? exhaust bellows // cooling system coolant circulation pump front type radiator for jacket water and charge aircooling circut with integrated expansion tank engine mounted fan drive // mounting system mounted on steel base frame resilent mounting of engine and generator // documentation & certi? cations genset & component manuals maintaince schedule ? ce-certification for eu fluids and lubricants specification // enclosures ? sound proof enclosure ? socket box ? increased fuel tank capacity
5 // / / mtu 10v1600 ds560 / 50 hz / 400 - 230v subject to change. | 3238021 | edition 02/14 | enc 2014-08. mtu onsite energy a rolls-royce power systems brand www.mtuonsiteenergy.com weights and dimensions rating definitions and conditions // standby ratings apply to installations served by a reliable utility source. the standby rating is applicable to varying loads f or the duration of a power outage. no overload capability for this rating. ratings are in accordance with iso 8528-1, iso 3046-1, bs 5514, as 2789 and din 6271. average load factor: < 85%, max. 500h/year. // derating factor: altitude: consult your local mtu onsite energy power generation distributor for altitude deratings. temperature: consult your local mtu onsite energy power generation distributor for temperature deratings. rated power for reference conditions at 25c and 100m above sea level. system dimensions (l x w x h) weight (wet/with standard accessories) open power unit (opu) 3.600 x 1.604 x 2.121 mm 4.002 kg enclosed power unit 4.500 x 1.800 x 2.340 mm 5.712 kg consult the factory for accurate weights and dimensions for your speci? c engine-generator set. lengths may vary with other voltages. do not use for installation design. materials and speci? cations subject to change without notice. drawing above for illustration purposes only, based on standard open and enclosed power 400 volt engine-generator set. lengths may vary with other voltages. do not use for installation design. see website for unit speci? c template drawings. sound data unit type open power unit: db(a) on request enclosed power unit: db(a) 68.2 sound data is provided at 7m for 75% prime power.


▲Up To Search▲   

 
Price & Availability of MTU10V1600DS560

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X